Endress+Hauser Levelflex FMP51 Mode D'emploi page 38

Masquer les pouces Voir aussi pour Levelflex FMP51:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

XA00497F-C
FMP51
Position 3 (Hilfsenergie; Ausgang / Power Supply; Output / Alimentation; Sortie) = A (TRC [03])
Position 5 (Gehäuse / Housing / Boîtier) = B
Temperaturklasse /
Temperature class /
Classe de température
T6 ( 85 °C)
T5 (100 °C)
T4 (135 °C)
T3 (200 °C)
Position 5 (Gehäuse / Housing / Boîtier) = C
Temperaturklasse /
Temperature class /
Classe de température
T6 ( 85 °C)
T5 (100 °C)
T4 (135 °C)
T3 (200 °C)
FMP52
Position 3 (Hilfsenergie; Ausgang / Power Supply; Output / Alimentation; Sortie) = A (TRC [03])
Position 5 (Gehäuse / Housing / Boîtier) = B
Temperaturklasse /
Temperature class /
Classe de température
T6 ( 85 °C)
T5 (100 °C)
T4 (135 °C)
T3 (200 °C)
Position 5 (Gehäuse / Housing / Boîtier) = C
Temperaturklasse /
Temperature class /
Classe de température
T6 ( 85 °C)
T5 (100 °C)
T4 (135 °C)
T3 (200 °C)
38
Sondendesign: kompakt / Probe design: compact / Construction de sonde: compacte
Ex nA
Sonde und Elektronikgehäuse / Probe and electronics housing /
Sonde et boîtier de l'électronique: Zone 2
P 1
P 2
T
T
T
p
a
p
–40 °C
60 °C
60 °C
60 °C
–40 °C
75 °C
75 °C
75 °C
–40 °C
80 °C
80 °C
80 °C
–40 °C
80 °C
80 °C
80 °C
P 1
P 2
T
T
T
p
a
p
–40 °C
60 °C
60 °C
60 °C
–40 °C
75 °C
75 °C
75 °C
–40 °C
80 °C
80 °C
80 °C
–40 °C
80 °C
80 °C
80 °C
P 1
P 2
T
T
T
p
a
p
–50 °C
60 °C
60 °C
60 °C
–50 °C
75 °C
75 °C
75 °C
–50 °C
80 °C
80 °C
80 °C
–50 °C
80 °C
80 °C
80 °C
P 1
P 2
T
T
T
p
a
p
–50 °C
60 °C
60 °C
60 °C
–50 °C
75 °C
75 °C
75 °C
–50 °C
80 °C
80 °C
80 °C
–50 °C
80 °C
80 °C
80 °C
P 3
P 4
T
T
T
T
a
p
a
p
85 °C
52 °C
85 °C
100 °C
67 °C
100 °C
135 °C
67 °C
135 °C
200 °C
49 °C
200 °C
P 3
P 4
T
T
T
T
a
p
a
p
85 °C
54 °C
85 °C
100 °C
69 °C
100 °C
135 °C
69 °C
135 °C
200 °C
56 °C
200 °C
P 3
P 4
T
T
T
T
a
p
a
p
85 °C
53 °C
85 °C
100 °C
68 °C
100 °C
135 °C
68 °C
135 °C
200 °C
53 °C
200 °C
P 3
P 4
T
T
T
T
a
p
a
p
85 °C
55 °C
85 °C
100 °C
70 °C
100 °C
135 °C
70 °C
135 °C
200 °C
58 °C
200 °C
P 5
P 6
T
T
T
T
a
p
a
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
P 5
P 6
T
T
T
T
a
p
a
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
–40 °C
P 5
P 6
T
T
T
T
a
p
a
–40 °C
–40 °C
–40 °C
–50 °C
–40 °C
–40 °C
–40 °C
–50 °C
–40 °C
–40 °C
–40 °C
–50 °C
–40 °C
–40 °C
–40 °C
–50 °C
P 5
P 6
T
T
T
T
a
p
a
–40 °C
–40 °C
–40 °C
–50 °C
–40 °C
–40 °C
–40 °C
–50 °C
–40 °C
–40 °C
–40 °C
–50 °C
–40 °C
–40 °C
–40 °C
–50 °C
Endress+Hauser
Levelflex
T
p
a
-
-
-
-
-
-
-
-
T
p
a
-
-
-
-
-
-
-
-
T
p
a
–37 °C
–37 °C
–37 °C
–37 °C
T
p
a
–38 °C
–38 °C
–38 °C
–38 °C