Abus Terxon SX AZ4301 Manuel D'installation page 125

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Omit Al+Tamp
You can block some zones and tamper
1
zones or a tamper alarm from
monitoring.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
053 Cancel - Reset
To change the property of the alarm reset:
1. On the control unit, enter:
2. The LCD display shows: 053:Abort=System
3. Via the keypad, select from the following items
and press:
Abort=System
0
Resetting after a cancelled alarm is as
set in function 33.
Abort=User
1
The user may make a reset after a
cancelled alarm.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
060 Entry/exit behaviour on internal active
(B)
To change the zone property of the entry/exit zone at
internal active (B):
1. On the control unit, enter:
2. The LCD display shows: 060: B=FE =FE
3. Via the keypad, select from the following items
and press:
B=FE =FE
A zone programmed as entry/exit keeps
0
this property even for internal activation
and thus starts the entry delay time
053
060
49
when the zone triggers and during
active internal activation.
B=FE = NA
A zone programmed as entry/exit
changes its zone property during
1
internal activation to immediate and
triggers an alarm if the zone triggers
and during active internal activation.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
061 Entry to follow behaviour on internal
active (B)
To change the zone property for internal active (B):
1. On the control unit, enter:
2. The LCD display shows: 061: B=ER =ER
3. Via the keypad, select from the following items
and press:
B=ER =ER
A zone programmed as entry to follow
0
keeps this property even during internal
activation and permits entry to this zone
during the entry delay period.
B=ER = FE
A zone programmed as entry to follow
changes its zone property during
1
internal activation to entry/exit and
starts the delay time if the zone triggers
and during active internal activation.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double "beep" tone and shows Installer Mode.
061
UK

Publicité

Table des Matières
loading