Jumper Settings; Led Indication; Technical Specifications - GE EV1000PI Série Manuel D'installation

Un détecteur de mouvements infrarouge
Table des Matières

Publicité

2
&
J1: Not used.
J2:
LED on.
LED off.
(
J3 and J4: See Figure
.
(
Installation instructions
EN
Introduction
The EV1012PI is made up of a PIR motion sensor with pet friendly optics.
Installation guidelines
The technology used in these detectors resists false alarm hazards.
However, avoid potential causes of instability such as (see Fig.
Direct sunlight on the detector.
Heat sources within the detector's field of view.
Strong draughts onto the detector.
Animals above 35 cm (1 ft.) within the detector field of view
Obscuring the detector field of view with large objects, such as
furniture.
Installing the detector
1.
Lift off the custom insert and remove the screw if enclosed
"
(see Fig.
, step 1).
2.
Using a screwdriver, carefully prise open the detector (see Fig.
steps 2 and 3).
3.
Fix the base to the wall between 2.3 m and 3.0 m (7.5 and 9.8 ft.) from
the floor. For flat mounting use a minimum of two screws (DIN 7998)
in positions A. For corner-mounting use screws in positions B or C
#
(Fig.
). To install a pry-off tamper, use position A or C.
4.
Wire the detector (see Figs.
5.
Select the desired jumper settings (see Fig.
the detector for more information.
6.
Remove the blinders and add the stickers, if required (see Fig.
an example)
7.
For ceiling-mount applications that require a 90° coverage use the
SB01 swivel-mount bracket.
8.
Close the cover.
9.
Insert the screw (if required) and place the custom insert.
'
!
'
#
(
and
).
&
). See section Setting
Setting the detector

Jumper settings

&
See figure
J1: Not used
J2: PIR enabling the LED
On:
):
Off:
J3 and J4: Dual loop setting
This sets the alarm and tamper relays. It allows you to connect the
detector to any control panel. Use jumpers 3 and 4. See figure
.

LED indication

Continuously on
PIR
Start up
"
,
Low voltage
PIR intruder alarm

Technical specifications

Detector
Signal processing
Range
Optical
%
for
Memory
Input power
Peak-to-peak ripple
Detector start-up time
Normal current consumption (mA)
Max 35 cm (1 ft.)
for the jumper locations in the detector.
Enables the detector LED at all times (ex-factory).
Puts the LED under control of the control panel and disables
the detector LED at all times (no memory feature).
Normal blinking (1 Hz)
Red LED Alarm relay
Closed
Open (Alarm)
Open (Alarm)
9 VDC to15 VDC (12 V nominal)
EV1000PI Series
Installation instructions
(
.
To reset
Automatically after 25 s
Apply correct voltage
Automatically after 3 s
PIR
DSP
12 m (39' 4")
9 curtains pet-friendly
No
2 V (at 12 VDC)
25 s
4.4

Publicité

Table des Matières
loading

Table des Matières