aircon Eco Power 9000 3in1 Manuel D'instructions page 37

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The warm extract air must be emitted from the room via the air hose. This can be executed e.g. via a tilted
window, a door or wall aperture. Make sure that no warm outside air can enter the room. For effective
cooling, we recommend our selection of various accessories which reduce or prevent entry of warm air into
the room.
Place the function to "COOLING". Set the target temperature using the temperature control. The settable
temperature range is between 17 and 30 degrees target temperature. The unit must only be used in an
ambient temperature of maximum 32°C.
Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three
minutes. Cooling effect may require a further 10 minutes. Further information is available under the item, "Troubleshooting".
COOLING IN OUTDOOR OPERATION
The unit is outside the room to be cooled.
Connect the air hose and the air outlet grid to the unit as displayed in the illustration; the air hose
connection piece and air outlet grid need to be exchanged.
Place the unit in the shade if possible and in a cool place in order to increase efficiency and to avoid
overheating. At an ambient temperature of over 32 degrees, the unit may deactivate. If this occurs
continuously, we recommend you temporarily use the INDOOR OPERATION of the unit. We recommend
that a drainage hose for condensation water be connected.
Set the function to "COOLING". The settable temperature range is between 17 and 30 degrees. This can be
set using the temperature control.
The air with high oxygen content cooled by the unit is fed into the room via the air hose. This can be
executed e.g. via a tilted window, a door or wall aperture. Make sure that no warm outside air can enter the
room. For effective cooling, we recommend our selection of various accessories which reduce or prevent
entry of warm air into the room, or via the remote control.
Using the various "Comfort Control Kits" you can also control the unit from inside using the remote control.
After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has flashed for three minutes.
Cooling effect may require a further 10 minutes. Further information is available under the item, "Troubleshooting".
HEATING
 On cold days it is recommendable to start the unit early in order to avoid intensive cooling of the room.
 For the heating function and to improve the heating effect and avoid lower temperatures (lower than 17°C)
we recommend you remove the rubber plug from the condensation water outlet and allow the
condensatation water to leak out of the unit using the drainage hose. However, the drainage hose does not
have to be connected in the heating mode, Please make sure that the condesnation water outlet is closed
with the rubber cap during operation. In such a case, proceed analogously to the emptying of the water tank
in the cooling function.
 The heating function of the unit must not be operated at a room temperature of more than 23°C or less than
7°C. The unit can also be operated with heating function, if the outside temperature is lower than 7°C.
However, you must then ensure that the unit is operated inside and the room temperature is at least 7°C.
Caution: In the heating mode, separate setting of the ventilator is not provided, since the highest
ventilation level is already preset to avoid overheating of the unit.
36

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Pc26-amb

Table des Matières