Vertical Installations
Always maintain a 1" clearance around the vent pipe (vertical) and 1" clearance horizontal, when passing
through ceilings, walls, roofs, enclosures, attic rafter or any combustible surfaces.
When passing through a flat ceiling install a Box/Wall thimble. Cut an 11" square hole and frame as shown
in the diagram below.
ALWAYS CHECK YOUR LOCAL CODES BEFORE INSTALLING VENTING. CLEARANCES ETC,
TOUJOURS vérifier les codes locaux avant l'installation VENTILATION. ETC DÉGAGEMENTS, peut
CONSULT DURAVENT PARTS LIST OR INCA METAL CUTTING PARTS LIST FOR PART
NUMBERS. FOR SECURITY CHIMNEY, ICC AND METAL FAB CONTACT YOUR LOCAL SUPPLIER.
CONSULTEZ LA LISTE DES PIÈCES DURAVENT OU LA LISTE DES PIÈCES DE DÉCOUPE
MÉTALLIQUES INCA POUR LES NUMÉROS DE PIÈCES. POUR LA CHEMINÉE DE SÉCURITÉ, ICC
See section 3.3.3 Venting for instructions on how to connect Security or Dura-vent
venting.
DO NOT PACK AIR SPACES WITH INSULATION
NE PAS PACK ESPACES D'AIR AVEC ISOLATION
11" x 11"
opening
MAY VARY FROM STATE TO STATE (PROVINCE TO PROVINCE).
varier d'ÉTAT (PROVINCE).
ET METAL FAB, CONTACTEZ VOTRE FOURNISSEUR LOCAL.