Installation and connection
➤ Connect the green cable (fig. 5 5, page 5) to the positive cable of the reversing light.
I
NOTE
On some vehicles, the reversing light only works when the ignition is switched on. In
this case, you must switch on the ignition to identify the positive and earth cables.
➤ Connect the black cable with the round plug lug (fig. 5 7, page 5) to the monitor connection
labelled S/BY or to the violet-white cable of NAV-7300 navigation system monitor.
The monitor receives its activation signal via this cable.
➤ Connect the plug (fig. 5 3, page 5) to the monitor.
➤ Connect the plug (fig. 5 4, page 5) to the camera.
A
NOTICE!
Ensure that all cables are connected correctly. The control line may never be
connected to earth; doing so can damage the device. Make especially sure to insulate
the bare end of the control line when it is not in use and thus not connected.
If a video source in addition to the reversing video camera – such as a navigation system or DVD
player – is connected to the monitor and you would like to activate the camera when parked or
moving fowards, you need to connect the black control cable with the flat plug lug to the
RV-AMP-SW rocker switch.
To do this, proceed as follows:
➤ Select a suitable installation location for the switch, such as on the dashboard near the monitor.
A
NOTICE!
Before drilling any holes, ensure that no electrical cables or other parts of the vehicle
can be damaged by drilling, sawing and filing.
➤ Drill a hole approximately 20 mm in diameter.
➤ Mount the switch.
➤ Plug the black cable with flat plug lug (fig. 5 6, page 5) into a connection on the switch.
A
NOTICE!
Ensure that you connect the other connection correctly to + PLUS and not to earth.
Connecting the control cables to earth can damage the device.
➤ Connect the other switch connection to a positive line with 12 V to 24 V.