EXAMPLE OF AN
ACCEPTABLE
BYPASS DESIGN
EN
SEASONAL
DAMPER
LOCATION

6.7.1 SEASONAL DAMPER POSITIONS

DAMPER ORIENTATION "WINTER MODE"
All three dampers are in the horizontal position
blocking air fl ow through the bypass plenum and
forcing air through the furnace loop.
W415-1504 / B / 11.30.16
*
SUPPLY
PLENUM
BYPASS
PLENUM
*
RETURN
PLENUM
*
DAMPER ORIENTATION "SUMMER MODE"
All three dampers are in the vertical position blocking
air fl ow on both the return and the supply ends of the
wood furnace, forcing air fl ow through the air condi-
tioning evaporator coil.
EVAPORATOR
COIL POSTION
HMFK-BMP50 BLOWER
MODULE OR HMFK-GT
TRANSITION KIT (HMFK-
GT WITH NPV060 GAS
FURNACE SHOWN)
SEASONAL DAMPER