Quick Start Guide - nedis WIFIACMB1WT9 Guide De Démarrage Rapide

Masquer les pouces Voir aussi pour WIFIACMB1WT9:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
a

Quick start guide

Wi-Fi Smart Air
Conditioner
For more information see
the extended manual online:
ned.is/wifiacmb1wt9 | ned.is/wifiacmb1wt12
Intended use
The Nedis WIFIACMB1WT9 | WIFIACMB1WT12 is a mobile air
conditioner used for cooling and dehumidifying rooms.
The product can be controlled with the Nedis SmartLife app via a
Wi-Fi connection from any location.
The product is exclusively intended as a mobile air conditioner for
domestic, indoor use.
The product is not intended for professional use.
Any modification of the product may have consequences for safety,
warranty and proper functioning.
Main parts (image A)
1
Continuous drainage outlet
2
Air outlet
3
Manual drainage outlet
4
Power cable
5
Power cable storage
6
Air intake
7
Swing louvers
8
Control panel
Safety instructions
-
WARNING
Thoroughly read all warnings.
This user manual is addressed to the end user. Read this
information carefully before installing or using the product.
Only use the product as described in this manual.
This product can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have
been given supervision or instruction concerning use of the
product in a safe way and understand the hazards involved.
Children shall not play with the product. Cleaning and user
maintenance shall not be done by children without supervision.
Close supervision is necessary when the product is used by or
near children, animals or infirm persons. Do not allow children to
play with it or touch it.
Keep the product out of reach from children.
Do not use a damaged or defective product, but return it for
repair or replacement.
Do not expose the product to water, rain, moisture or high
humidity.
If the product is immersed in water, do not touch the product or
the water.
Shut off the main power grid and carefully remove the plug from
the power outlet.
After the product has been immersed or covered in water or
other liquids, do not use the product again.
Keep the product away from heat sources. Do not place the
product on hot surfaces or near open flames.
Do not use the product near explosive or flammable materials.
Do not insert any objects into the product.
Do not obstruct or cover the product's air inlet or outlet grid.
Always disconnect the product from the power outlet when
cleaning or moving the product.
Do not pull the power cable to move the product.
WIFIACMB1WT9
WIFIACMB1WT12
9
Exhaust hose
10
Exhaust nozzle
11
Exhaust hose connector
12
Window kit
13
Remote control
14
Window kit fasteners
15
Exhaust nozzle screw
This product may only be serviced by a qualified technician for
maintenance to reduce the risk of electric shock.
Disconnect the product from the power outlet and other
equipment if problems occur.
Turn off the main power switch before unplugging the power
cord.
Do not use the product when the cord or plug is damaged.
Make sure that the electrical supply in your area matches a
voltage of 220 – 240 VAC and a frequency of 50 Hz.
Connect to a grounded socket only.
If necessary, use an earthed extension cable of a suitable
diameter.
Fully extend the power cord and make sure the power cord does
not contact the product.
When using an extension cord, use one which is as short as
possible and fully extended.
Do not use external timers or remote control systems to switch
the product on or off.
Ensure people do not trip over the cord.
Make sure that the power cable cannot become entangled and
does not hang over the edge of a worktop.
Do not leave the product unattended when switched on.
R290 is a refrigerant gas that complies with the European
directives on the environment.
Be aware that refrigerants can be odorless.
Place the product in an area without any continuous sources of
ignition (for example: open flames, gas or electrical appliances in
operation).
Only install, operate and store the product in a room with a floor
area above 11 m
.
2
Only store the product in a well-ventilated area.
Store the product in such a way as to prevent mechanical failure.
When the product is installed, operated or stored in a
non-ventilated area, make sure the room is designed to prevent
the accumulation of refrigerant leaks resulting in a risk of fire or
explosion due to ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
Only persons with a current valid certificate from an
industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an
industry recognized assessment specification, can work on or
break into a refrigerant circuit.
Servicing can only be performed as recommended by the
equipment manufacturer. Maintenance and repair requiring the
assistance of other skilled personnel can only be carried out
under the supervision of the person competent in the use of
flammable refrigerants.
When defrosting and cleaning the product, do not use any
means other than those recommended by the manufacturing
company.
Do not puncture or heat any part of the refrigerant circuit.
Installing the product
Place the product on a stable and flat surface.
-
-
Leave a minimum of 0.5 m space around the air inlet and outlet
to allow a good circulation of airflow.
Only move the product in an upright position.
-
-
If the product has been tilted, allow it to stand upright for 2 hours
before plugging it in.
Assembling the exhaust (image B)
-
Only use the provided exhaust hose.
-
Do not block the exhaust hose, this may cause overheating.
1. See image B.
Assembling the continuous drainage (optional)
1. Open the continuous drainage outlet A
5
1
.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wifiacmb1wt12

Table des Matières