Scope of supply
Pos.
Description
USB diagnostic adapter E94AZCUS
USB cable
Mounting Instructions
Connections
Pos.
Description
X61
USB connection
X6
Connection of the basic device (RJ69 socket)
Displays
LED
Pos.
Colour
Power
Green
Tx / Rx
Yellow
USB
Green
Technical data
Field
USB connection
(X61)
8
Condition
Description
On
Diagnostic adapter is supplied with voltage by the basic device.
Blinking
Basic device and PC communicate with each other via the
diagnostic adapter.
On
Diagnostic adapter is connected to the PC and configured via USB.
Details
Maximum current consumption: 100 mA
l
EDK94AZCUS DE/EN/FR/ES/IT 5.0