Dryer Fault Codes - Dexter Laundry T-50 Manuel De L'utilisateur

Masquer les pouces Voir aussi pour T-50:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

REVERSING DRYER CONTROLLER FACTORY DEFAULT PROGRAM
DRY
DRYER
CYCLE
DIRECTION
1
REV.
2
REV.
3
REV.
4
NON-REV.
5
NON-REV.
FAULT
FAULT #
DESCRIPTION
Shorted thermostat
F1
sensor.
Open thermostat
F2
sensor.
F3
EEPROM corrupted.
F4
Gas valve on fault.
F5
Temperature fault.
8514-262-001 REV G PAGE 22
SETTINGS
COOL
DOWN TIME
CYCLE TIME
(minutes)
(minutes)
5
2
5
2
2
REVERSING DRYER FAULT CODES
Dryer stops and "F1" flashes on the 4-digit display. When short circuit on
sensor input is removed, "LOAd" appears on the 4-digit display and the
remaining dry time is reset.
Dryer stops and "F2" flashes on the 4-digit display. When a good sensor is
connected to sensor input, "LOAd" appears on the 4-digit display and the
remaining dry time is reset.
Dryer will not start and "F3" appears on the 4-digit display. The power to the dryer
must be cycled to reset the controller. Fault should only occur when starting a dry
cycle.
The drying temperature did not increase 1°F. in 5 minutes. "F4" will flash on the
display and the dry cycle will finish without calling for heat (energizing gas valve).
Opening the door or pressing the STOP touch pad switch will reset the fault and
clear the remaining time in the dry cycle.
The drying temperature is at least 25°F. above the temperature setting. "F5" will flash
on the 4-digit display and the dry cycle will finish without calling for heat (energizing
the gas valve). The power to the dryer must be cycled to reset the controller.
DRYING
TOTAL
TEMPERATURE
(ºF)
35
180
20
170
25
180
20
130
25
175
ACTION
DRYER LOAD
(ºC)
Towels, pads,
82
heavy cotton
Sheets, blended
77
materials
82
Cotton
Synthetic
54
Materials
79
Blended Materials

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

T-80T-120T-170T-30

Table des Matières