Wiring Diagram; Important Warning - dirna Bergstrom SCANIA PGR bycool DINAMIC 1.1 Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 34
DINAMIC 1.1
Take care not to invert polarities when connecting the unit to the power supply. If this happens, the control
panel does not come on and the unit does not work.
Condenser
fan

IMPORTANT WARNING!

Return
air sensor
Blower
Anti-freeze sensor
Fuse box
33

Wiring diagram

-
+
ºC
ºF
TEMP
Electronic control
Az
Blue
N
Black
R
Red
V
Green
B
White
A
Yellow
Compressor
E-Modul
Na
Orange
M
Brown
Compressor