Maintaining And Cleaning The Device; Troubleshooting - Dometic GROUP WAECO CombiPower 2012 Notice D'utilisation

Onduleur sinusoïdal avec chargeur automatique intégré
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

_CombiPower_BA_DE-IT.book Seite 57 Freitag, 21. Oktober 2011 8:10 20
CombiPower
7

Maintaining and cleaning the device

NOTICE!
A
Do not use any sharp or hard objects for cleaning since they may
damage the device.
➤ Disconnect the device from the 230 V power supply.
➤ Disconnect the device from the battery.
➤ Prevent the device from being switched on.
➤ Occasionally clean the device with a damp cloth.
➤ Regularly clean the vents.
➤ Check the electrical wiring at least once a year.
Repair any defects such as loose connections or burnt cables.
8

Troubleshooting

Fault
No output voltage at "INV.
AC OUTPUT" and "AC OUT-
PUT" and no charging cur-
rent; no LED lights up
No output voltage, "Alarm"
LED lights up red, display
shows "Overload Alert"
No output voltage, "Alarm"
LED lights up red, display
shows "UV Alert"
EN
Maintaining and cleaning the device
Cause
The device is switched off
The device is defective
No contact to the battery
Battery discharged
Battery defective
Defective fuse (in the device or
the vehicle)
The device is at 100% load
Battery voltage too low
Remedy
Check the main switch
Replace the device
Check the contact and cables
Switch on the ignition if nec-
essary
Charge the battery
Replace the battery
Replace the fuse with one of
the same rating
Reduce the load (switch off
consumer units)
Switch off the device and on
again
Charge the battery
57