Configuring the device with the remote control
Deactivating the inverter function
➤ Switch on the device (see chapter "Switching the device on and off" on
page 48).
➤ Press the
"
✓ You are now in setup mode.
➤ Use the "▼" or "▲" button to navigate to the "Change Run Mode" menu.
➤ Press the
"
➤ Use the "▼" or "▲" button to navigate to the "CHR Power On" parameter.
➤ Briefly press the
6.4
Limiting the input current at the 230 V input
(power sharing level)
You can restrict the input current at the 230 V input if the available electricity
connection is limited.
This is how to limit the input current at the 230 V input:
➤ Switch on the device (see chapter "Switching the device on and off" on
page 48).
➤ Press the
"
✓ You are now in setup mode.
➤ Use the "▼" or "▲" button to navigate to the "P.S. Mode Param" menu.
➤ Press the
"
➤ Use the "▼" or "▲" button to navigate to the "Iac setup" parameter.
➤ Press the
"
➤ Use the "▼" or "▲" button to set the input current.
➤ Briefly press the
56
" button on the remote control for longer than 2 seconds.
" button to select the menu.
" button to save the parameter.
"
" button on the remote control for longer than 2 seconds.
" button to select the menu.
" button to select the parameter.
" button to save the value.
"