6
SPÉCIFICATIONS
6-1 SPÉCIFICATIONS
Model
Range
Maximum arrival distance
Detection method
Beam frequency selection
Variable between 50, 100, 250, 500msec
Interruption period
Power Source
Transmitter : 2 units
Current draw
T:300µA + R:320µA
* Battery life
Alarm output
Form C-Solid State Switch : 3.6VDC, 0.01A
Alarm period
D.Q. output
Form A/B-Solid State Switch : 3.6VDC, 0.01A
Form A/B-Solid State Switch: 3.6VDC, 0.01A
Low battery output
Output
** Tamper output
opens when cover removed. (Receiver only)
for Front cover
Tamper output
for Back box
Alarm Indicator
(Receiver)
Power
Indicator
(Transmitter)
Low battery
Operating temperature
Operating ambient
humidity
Alignment angle
Mounting
required, when the units mount in the tower.)
Weight
International protection
Specifications and design are subject to change without prior notice.
* The value is based on the condition that it is used within the
ambient temperature range of 20 to 25°C.
** The transmitter is also equipped with AX100/200 TFR (BE).
OPTEX CO., LTD. (JAPAN)
(ISO 9001 Certified)
(ISO 14001 Certified)
5-8-12 Ogoto Otsu
Shiga 520-0101
JAPAN
TEL:+81-77-579-8670
FAX:+81-77-579-8190
URL:http://www.optex.co.jp/e/
AX-100TFR
AX-200TFR
30m (100ft.)
60m (200ft.)
265m (870ft.)
530m (1,740ft.)
Infrared beam interruption detection
4 channel
(4 steps)
3.6V 13.0Ah : LSH20 lithium batteries
manufactured by SAFT
Receiver : 2 units
620µA
810µA
T:490µA + R:320µA
(at 25°C,3.6VDC)
(at 25°C,3.6VDC)
Approximately
Approximately
5 years
3 years
2 sec (± 1) nominal
(Transmitter & Receiver)
Form C : 3.6VDC, 0.01A
Form C : 3.6VDC, 0.01A
opens when either back box or chassis is
removed from the installment.
Alarm : ON,
Light receiving : flicker or OFF
Power ON : ON,
Power OFF : OFF
Voltage Reduction : flicker
-20°C – +60°C(-4°F – 140°F)
95%(Max.)
± 90° Horizontal, ± 5° Vertical
Indoor/Outdoor, Wall/Pole/Tower mounting
(Optional main unit mounting brackets are
1600g (56.5oz)
(Total weight of transmitter + receiver,
excluding accessories)
IP55
OPTEX INCORPORATED (USA)
TEL:+1-909-993-5770
Tech:(800)966-7839
URL:http://www.optexamerica.com/
OPTEX (EUROPE) LTD. (UK)
TEL:+44-1628-631000
URL:http://www.optex-europe.com/
OPTEX SECURITY SAS (FRANCE)
TEL:+33-437-55-50-50
URL:http://www.optex-security.com/
6-2 DIMENSIONS & OPTION
-Dimensions
88,1(3,47)
-Option
MP-4 : Ensemble de support principal de montage de l'unité
(pour montage sur tour)
Support de montage de
l'unité principale
REMARQUE
Ces appareils sont conçus pour détecter un intrus et pour actionner
un panneau de contrôle d'alarme. Comme ils font partie d'un
système complet, nous ne pouvons accepter aucune responsabilité
pour aucun dommage ou autre conséquence d'une intrusion.
Ces produits sont conformes à la Directive EMC 2004/108/EC.
-12-
162,5(6,4)
Unité : mm (pouce)
Bague d'autoprotection
Unité : mm (pouce)
OPTEX SECURITY Sp. z o. o. (POLAND)
TEL:+48-22-598-06-55
URL:http://www.optex.com.pl/
OPTEX KOREA CO., LTD. (KOREA)
TEL:+82-2-719-5971
URL:http://www.optexkorea.com/
OPTEX (DONGGUAN) CO., LTD.
SHENZHEN OFFICE (CHINA)
TEL:+86-755-33302950
URL:http://www.optexchina.com/

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ax-200 tfr

Table des Matières