INSTALLATION INSTRUCTION

The relay plug-in card is plugged into the electronic circuits of the SHT 5000 water detector.
For this, the housing of the SHT 5000 water detector must be opened.
Warning: Before opening the device, first disconnect it from any power
source (network power, etc.) and ensure that it cannot be restarted again!
Place the relay plug-in board onto the 6-pin jack provided. Use the spacer sleeves supplied
to secure the board.
L
L
Operating voltage
210-250 V
Relay connection configuration
When connecting additional devices to the potential-free relay, please note that the switching
capacity may not be exceeded.
Relay status in alarm mode: The relay „decreases" (make contact open/ break
contact closed)
Relay status in monitoring mode: The relay is „energized" (make contact closed/break
contact open)
S
G
Ö
Relay
8A/230V
Relay plug-in card
connection
L
N
N
PE
PE
S
G
Ö
N PE
Sensor 1
Float switch
50-60 Hz
S
G
Ö
S
Option:
9V battery
Sensor 3
Sensor 4
Sensor 2
Float switch
Float switch
Float switch
G
Ö
S
G
Ö
Relay
5 A / 230 V
S
G
Ö