Safety Features; Overheat Protector - Toyotomi FF-55T Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT
1) READ AND UNDERSTAND INSTRUCTIONS BEFORE INSTALLING OR USING HEATER.
2) RETAIN INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE.
3) CHECK LOCAL AUTHORITY & BUILDING CODES FOR INSTALLATION REQUIREMENTS.
SECTION A:
SPECIFICATIONS
Model:
Heater Efficiency:
Heat Rating:
Fuel Consumption:
Fuel System:
Fuel Type:
Dimensions (W × H × D):
Weight:
Vent Pipe Hole:
Maximum Length of Vent Pipe System:
Electrical Rating:
(1)
Heat and vaporized water are produced by fuel combustion. Heat rating does not account for heat loss due to
condensation of water vapor.
(2)
External tank to be purchased separately. (Consult your supplier for options.)
(3)
It is excluded from CE marking.
Your heater is equipped with a number
of integral safety features. Please famil-
iarize yourself with these features. If the
heater shuts down due to the operation of
any safety device, ensure the problem is
identified and corrected. Note that normal
combustion flames inside the combustion
chamber, can be seen through a "peep
hole", located in the front bottom left
hand corner of the hot air outlet louver's.
1. Flame Sensor
Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order to prevent
fuel overflow. Error code will be displayed on the digital indicator.
2. Fuel Strainer
Special strainer catches any dirt or impurities present in the fuel before it is sent to the burner.

3. Overheat Protector

Automatically stops all operations if heater cabinet reaches abnormally high temperature due to motor malfunc-
tion or abnormal combustion, in order to prevent fire.
4. Power Failure Recovery System
If power fails during heater operation, heater will turn off. When power resumes, heater will automatically reignite
and maintain the normal selected temperature.
NOTE: The operation varies depending on the time length of power failure and other conditions.
,
Please see Section E "Operation" for more details.
5. Fully Vented System
Flue pipe system provides outside air for combustion and vents all combustion products to the outdoors.
1
FF-55T/FF-55
92.4% (1)
High - 5.50 kW (18,800 BTU/h)
Med - 3.74 kW (12,800 BTU/h)
Low - 1.88 kW ( 6,430 BTU/h)
High - 0.622 L/h
Med - 0.423 L/h
Low - 0.213 L/h
Removable fuel tank (7.6 L) / External tank (2)
Paraffin only
496 × 600 × 339 mm
20 kg/17 kg
70 ~ 80 mm diameter
3 m, 3 bents or less (Section I "Installation")
230 Volts AC, 50 Hz
(220 Volts AC, 50/60 Hz) (3)
Preheat - 260W
Burning - 48W

SAFETY FEATURES

Overheat protector
Heat shield plate
Heat exchanger
Peep hole
Flame sensor
Burner ring
Burner
Igniter
Fuel pipe
Blower motor
FF-55T
Overheat protector
Heat shield plate
Removable
fuel tank
Heat exchanger
Fuel pump
Peep hole
Flame sensor
Fuel sub tank
Fuel
acceptance
fitting
Burner ring
Burner
Igniter
Fuel pipe
FF-55
ENGLISH
Fuel pump
Red reset button
Integral
fuel strainer
(inside)
Fuel sump
Blower motor

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ff-55

Table des Matières