MODEL
PERFORMANCE CONDITION: Air 27°C/Water 27°C/RH 80%
Heating capacity
COP range
Average COP at 50% Speed
PERFORMANCE CONDITION: Air 15°C/Water 26°C/RH 70%
Heating capacity
COP range
Average COP at 50% Speed
PERFORMANCE CONDITION: Air 35°C/Water 28°C/RH 80%
Cooling capacity
TECHNICAL SPECIFICATIONS
Operating air temperature
Water heat temperature set range
Water cool temperature set range
POWER SUPPLY
Rated input power
Rated input current
Maximum input current
Rated RCD type B
Rated Fuse aM / MCB type C
Sound pressure level at 10m
Recommended water flow rate
Pressure drop
Pool water connections
GENERAL DATA
Net dimensions (w x d x h)
Packed dimensions (w x d x h)
Net weight
HERMETIC SYSYEM
Refrigerant charge R32
Minimum area requirement
NOTES: Heat pump performance parameters are subject to change without notice. Always refer to the
nameplate. Global warming potential (GWP) R32 - 675.
The data is subject to modification without prior warning.
1007332 ISSUE 5
UNITS
HPP-iw 12
kW
15.0
15.0-6.6
10.6
kW
10.5
7.7-4.6
6.4
kW
6.7
°C
°C
°C
230V Single Phase 50Hz
kW
0.27-2.28
A
1.17-9.91
A
13.5
mA
30
A
20
dB(A)
20.8-24.5
m
/h
5.0-7.0
3
m/kPa
0.49/4.8
Inches
mm
954x359x648
mm
1040x445x655
kg
52
kg
0.9
m2
6.9
HPP-iw 16
HPP-iw 22
21.0
27.5
14.8-6.4
15.0-6.8
10.3
10.3
14.5
18.0
7.1-4.6
7.5-4.6
6.3
6.3
9.5
11.9
-10°C to 43°C
18°C to 40°C
12°C to 30°C
400V Three Phase 50Hz
0.41-3.15
0.48-3.91
0.59-4.56
0.69-5.66
5.8
30
30
10
10
20.4-33.7
23.0-34.4
8.0-10.0
10.0-12.0
0.61/6.0
0.77/7.5
1½" or 50mm Female
954x429x755 1084x429x948 1154x539x948
1040x445x770 1130x445x985 1200x5555x985
68
93
1.2
2.0
12.3
34.0
HPP-iw 28
36.0
14.8-6.0
10.2
23.9
7.5-4.6
6.3
16.0
0.64-5.20
0.92-7.53
7
9.5
30
16
22.1-34.2
12.0-18.0
0.85-8.5
120
2.7
62.0
37