Emglo Air-Mate AM782HC4V Guide D'utilisation page 19

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

All manuals and user guides at all-guides.com
CODE
POSSIBLE CAUSE
4
Defective air tank
5
Leaking seals
6
Defective safety valve
7
Regulator is not adjusted correctly for accessory being
used
8
Prolonged excessive use of air
9
Compressor is not large enough for accessory
10
Hole in air hose
11
Check valve restricted
12
Air leaks
13
Regulator is damaged
14
Unit operating in damp or humid conditions
15
Restricted air intake filter
16
Pump oil is low
POSSIBLE SOLUTION
Air tank must be replaced. Do not repair the leak.
WARNING: Risk of bursting. Do not drill into, weld or
otherwise modify air tank or it will weaken. The air tank can
rupture or explode.
Contact an authorized service center.
Operate safety valve manually by pulling on ring. If valve
still leaks, it must be replaced.
It is normal for some pressure drop to occur when an acces-
sory is used, adjust the regulator as instructed in Regulator
under Features if pressure drop is excessive.
NOTE: Adjust the regulated pressure under flow conditions
while accessory is being used.
Decrease amount of air usage.
Check the accessory air requirement. If it is higher than
the SCFM or pressure supplied by air compressor, a larger
compressor is needed to operate accessory.
Replace air hose.
Remove, clean or replace.
Tighten fittings.
Replace.
Move unit to a dry well ventilated area
Clean or replace air intake filter
Add ISO 100/SAE40, non-detergent, premium air com-
pressor oil to pump. See Compressor Pump Oil under
Maintenance.
19

Publicité

Table des Matières
loading

Produits Connexes pour Emglo Air-Mate AM782HC4V

Table des Matières