4. TROUBLESHOOTING
Following are a few common problems that may occur during operation. Here are some suggestions
for easy troubleshooting:
1. The fixture doesn't not work, no light :
1. Check the connection of power and main fuse
2. Measure the main voltage on the main connector
2. The fixture does not respond to DMX controller :
1. DMX LED should be on. If not, check DMX connectors, cables to see if link prperly
2. If the DMX LED is on and no response to the channel, check the address settings and DMX
polarity
3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of
the fixture or the previous one
4. Try to use another DMX controler
5. Check if the DMX cables run near or run alongside to high voltage cables that may cause
damage or interference to DMX interface circuit
FOR ANY PROBLEM OR MALFUNCTION, PLEASE CONTACT YOUR RESELLER