CAUTION
INSTALLATION MUST CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF
LOCAL CODES THE NATIONAL FUEL GAS CODE, ANSIZ223.11996.
CAUTION
THIS APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN
ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH
THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70-1996.
CAUTION
FOR INSTALLATION IN CANADA THE INSTALLATION MUST BE IN ACCORDANCE
WITH CAN/CGA-B149.1&2 OF THE INSTALLATION CODE, AND LOCAL CODES
WHERE APPLICABLE. ALL ELECTRIC WIRING MUST BE IN ACCORDANCE WITH
THE CURRENT CANADIAN ELECTRICAL CODE, C22.1 PART 1. GROUNDING THIS
APPLIANCE MUST CONFORM TO CANADIAN ELECTRICAL CODE, CSA C22.2.
WARNING
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED TO WORK
WITH ELECTRICITY AND PLUMBING IMPROPER INSTALLATION CAN CAUSE INJURY
TO PERSONNEL AND /OR DAMAGE TO EQUIPMENT. UNIT MUST BE INSTALLED IN
ACCORDANCE WITH ALL APPLICABLE CODES.
WARNING
DO NOT ALLOW ANY PART OF YOUR BODY TO BE UNDER THE OVEN DURING THE
LIFTING PROCESS. KEEP EVERYONE CLEAR FORM THE OVEN IF IT SHOULD FALL.
NOTICE
No other exhaust systems may be connected to this system. Do not try to vent or
exhaust another appliance into this hood.
NOTICE
Do not allow more than 14 inches pressure to be applied to the gas valve at any time.
CAUTION
TO REDUCE THE RISK OF FIRE, THE APPLIANCE IS TO BE MOUNTED ON FLOORS
OF NON-COMBUSTIBLE CONSTRUCTION WITH NONCOMBUSTABLE FLOORING,
SURFACE FINISH AND WITH NO COMBUSTIBLE MATERIAL AGAINST THE
UNDERSIDE THEREOF, OR ON NONCOMBUSTABLE SLABS OR ARCHES HAVING
NO COMBUSTIBLE MATERIAL AGAINST THE UNDERSIDE. SUCH CONSTRUCTION
SHALL EXTEND A MINIMUM OF 12 INCHES [300MM] BEYOND THE EQUIPMENT ON
ALL SIDES
Must Read
3/10/2017
Cautions 12