Bouton-poussoir de commande de store radio simple
Operating mode
Manual commissioning
Local Operation
Running time
Slat change-over time
Fabric-stretching time
Minimum change-over-time
Invert movement direction
Behaviour on voltage return
Configured venetian blind po-
sition
Configured slat position
Behaviour after the end of the
disabling function
32582622
10864996
Roller shutter
Venetian blind
Awning
Basic setting: Roller shutter
On, Off
Basic setting: On
On, Off
Basic setting: On
1 ... 600 sec
Basic setting: 120 s
0 ms ... 10 sec
300 ms ... 10 s
Basic setting: 0 ms / 300 ms
300 ms ... 10 sec
Basic setting: 1 s
On, Off
Basic setting: Off
No change
Configured value
Basic setting: No change
0 ... 100 %
Basic setting: 0 %
0 ... 100 %
Basic setting: 0 %
no change
Last value
Down
up
Basic setting: No change
22.03.2017
See Device and channels.
Blocks manual commissioning
for the device channel. In the
"Off" setting, the device can-
not be reset to the factory set-
ting.
Blocks the output for operation
using the button.
Absolute time which the
blind/shutter requires from the
top to the bottom end position.
The entry is essential if scene
or position movements are to
occur.
Absolute time for changing-
over Venetian blind slats. The
fabric stretching time can also
be set here for the Awning
operating mode.
Minimum interruption time
when changing directions. In-
creasing the minimum
change-over time will cause
less wear on the motors.
Inverts the activation of the re-
lay outputs. During inverted
operation, the relay outputs
"Up" and "Down" should be
activated in reverse. This is re-
quired, for example, for
controlling skylights.
Defines the behaviour of the
output after voltage return.
RMD design: Bus voltage re-
turn
If the value "Configured posi-
tion" is entered for the para-
meter "Behaviour after voltage
return", then the blind/shutter
position set here is approa-
ched.
If the value "Configured posi-
tion" is entered for the para-
meter "Behaviour after voltage
return", then the slat position
set here is approached.
Behaviour of the output when
a block is removed.
6/10