Report prepared for: Guillaume Thibodeau-Fortin (Stove Builder International Inc.) on 4/30/2018 7:18:14 AM
Test report 103328128MTL-001 (11 of 18)
Stove Builder International Inc.
Project No. G103328128
TABLE 5 - DILUTION TUNNEL DUAL TRAIN PRECISION
Run No.
1
3
4
2
TABLE 6 - GENERAL SUMMARY OF RESULTS
Run No.
1
2
3
4
TABLE 7 – CSA B415.1 RESULTS
Burn Rate
(kg/hr)(Dry)
High – 1.8
Medium – 1.3
Medium – 1.1
Low – 1.1
Please note: On the high burn rate (run #2), particulate emission rate is on the full sampling time of the
test run (including the cold-start). For the other parameters such as efficiency, CO emission rate and
burn rate, the time is only for the loading of the high fire (excluding the cold start).
Stove Builder International Inc. | 43615 | Rev: Apr 27 2018 2:35PM | Uncontrolled Copy
Sample Ratios
Train 1
Train 2
2863
2913
2713
2727
2679
2672
2858
2892
Change In
Burn Rate
Surface
(kg/hr)(Dry)
Temp (°F)
1.1
58
1.8
104
1.1
105
1.3
84
CO Emissions
(g/hr)
60
69
51
54
Total Emissions (g)
Train 1
Train 2
Deviation
6.013
6.408
6.510
6.818
4.287
4.543
8.002
8.386
Initial Draft
Run Time
(in/H
O)
(min)
2
0.038
350
0.076
178
0.045
360
0.047
300
Heating
Heating
Efficiency
Efficiency
(% HHV)
(% LHV)
67%
72%
68%
73%
71%
76%
72%
78%
Date: December 27, 2017
Page 11 of 18
%
g/kg
Deviation
3.18%
0.79%
2.31%
0.58%
2.89%
0.72%
2.34%
0.59%
Average
Draft
(in/H
O)
2
0.051
0.065
0.055
0.060
Heat Output
(Btu/hr)
23,300
17,180
14,680
15,650