Ferroli AQUA1 PLUS 160 HT Manuel D'installation Et Maintenance page 43

Masquer les pouces Voir aussi pour AQUA1 PLUS 160 HT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation and maintenance manual
Parameter description
Delay in equipment start-up
Delay as from last ON
Delay as from last OFF
Minimum ON time
Number of compressor operating hours
required for maintenance
Delay air temperature sample taking for
cold evaporator test
Minimum delay between fan start-up
and compressor activation for incoming
air temperature check
Timeout GREEN cycle
Delay for damaged fan check
Type of defrosting
Evaporator temperature to conclude
defrosting procedure (only if P4=1)
Maximum
duration
procedure
Automatic
defrosting
(evaporator temperature)
Minimum compressor start up time to
start defrosting procedure
Minimum level probe alarm (only AL1
warning)
Minimum alarm set (only AL1 warning)
Type of minimum level alarm delay (only
AL1 warning)
Maximum level probe alarm (only AH
warning)
Maximum alarm set(only AH warning)
Type of maximum level alarm delay (only
AH warning)
Minimum level AL1 alarm delay due to
equipment start-up (only warning)
AL1 and AH temperature alarm delays
(only warning)
Alarm hysteresis
Heating element start-up interval (Anti-
Legionella)
Code
C0
C1
C2
C3
C10
C11
C12
C13
C14
d1
d2
of
defrosting
d3
start
threshold
d17
d18
A0
A1
A2
A3
A4
A5
A6
A7
A11
H0
U.M.
Min
Max
min
0
240
min
0
240
min
0
240
sec
0
240
h
0
9999
min
0
999
min
0
240
min
0
240
min
-1
240
----
0
2
°C/°F
-50.0
50.0
min
0
99
°C/°F
-50.0
50.0
min
0
240
----
0
2
°C/°F
0.0
50.0
----
0
1
----
0
2
°C/°F
0.0
199.0
----
0
1
min
0
240
min
0
240
min
0.1
30.0
days
0
99
Default
Notes
can only be seen
5
5
Compressor protections
5
0
0
0 = Function excluded
120
1
20
20
-1 = disabled function
0 = With heating element
1 = With hot gas
1
2
=
With
compressor
stopped
25.0
8
-2.0
60
0 = Upper probe
0
1 = Lower probe
2 = Evaporator probe
10.0
0 = Disabled
0
1 = Absolute
0 = Upper probe
0
1 = Lower probe
2 = Evaporator probe
90.0
0 = Disabled
0
1 = Absolute
120
15
2.0
30
pag. 19 / 23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqua1 plus 200 htAqua1 plus 260 ht

Table des Matières