The Turbo/Speed Air is designed to quickly raise the temperature in your bathroom.
1
2
3
infrared receiver on Turbo/Speed Air
1. Filter cleaning indicator
2. Blower operation indicator
3. Towel warmer operation indicator
4. Infrared receiver cell
5. Start/towel dry button
SpEciFic cASES
overheating
If towels or any other obstructions block the Turbo/Speed
Air outlet excessively, causing overheating, the device will
shut down (indicators 2 and 3 blinking red / green). The
Turbo/Speed Air operation will restart once the temperature
cools, for the remaining preset length of time.
Thermal safety:
If the Turbo/Speed Air resistor overheats a manually reset
thermal safety device mechanically stops blower operation.
indicator light status:
• Filter indicator 1: Blinking red and
• Blower indicator 2: Steady green
TiMEr oN hoT wATEr vErSioN dEvicES
• Install the timer in the same room as the towel dryer. The
timer must be installed about 1.5 metres above the fl oor,
on an inside wall, away from splashing water, direct
sunlight and direct source of direct thermal disturbance.
2 | P16MI407 - A01 - 04/15
v8_MANUAL_TURBO_SPEED_AIR_04_2015_A4.indd 2
4
5
The infrared timer
transmitter lets you send
a start command to the
Turbo/Speed Air for a
variable period of 0 to 2
hours.

STArTiNg ThE dEvicE:

Put the switch located at the back of the control on the "I"
position to turn it on.
• Indicators 2 and 3: Steady green - Turbo/Speed Air +
Towel dryer turned on
• Filter indicator 1: Off
• Indicator 3: Steady red - towel dryer running
bLowEr 2 opErATiNg LighT:
• Off: Power Off
• Steady green: Power On
• Blinking red: Operating
important: A dirty fi lter can cause overheating. Clean it if
necessary. Press button 5 "start/stop" for 5 seconds to stop
this alarm.
Note: Please clean the fi lter each time the Clean Filter alarm
is triggered ("see Cleaning the Filter").
caution: if the cause of overheating has not been identifi ed
the alarm will be triggered again. In this case, please contact
the installer since this may cause the Turbo/Speed Air to
deteriorate over time.
Note: To ensure proper infrared transmission:
- Do not obstruct transmitter and receiver cells
(bath towels in front of the cell).
- Avoid using electronic ballast lighting in the same room.
• Set the dial for the desired time and press the "OK / Boost"
button to start the blower.
NoTE: Forced operation of the device can be interrupted at
any time by pressing the "OK / Boost" button again. When
restarting the blower in this case, the remaining Boost time
will be the setting shown on the dial.