P) Refill the oil tank as described in paragraph 10.6.
WARNING: It is recommended to avoid seizing that could cause the break of the fixed ring. After its insertion,
insert the rotating part of the seal itself.

15. Tools

Tools can only be used by DRENO POMPE qualified personnel. They are:
Allen keys, size: 14 mm
Seeger pliers
Phillips screwdriver
2 flat screwdrivers
Hexagon spanners: 24-30 mm

16. Troubleshooting

If the pump does not start, the reason may be one of the following:
No power supply (check if the fuses have blown, or if the circuit protection relay has
tripped)
The selection switch is in the OFF position (move it to ON)
No phase (check the connection)
Blocked impeller
Seized seal or bearings.
If the pump does not stop, the reason may be one of the following:
The stop regulator is faulty (clean or replace the stop regulator).
The pump is unable to empty the tank up to the stop level. There may be leaks in the
hydraulic system, or the ball intercept valve preventing the backflow of the liquid may be
faulty, or the pump may be working inside an air pocket,
or the pump may be undersized for the pumping level required.
If the pump is working, but the delivery level is insufficient, or there is no delivery, the reason
may be one of the following:
The pump direction of rotation is wrong (this is only possible with three-phase motors):
Check the wear of the hydraulic section.
The pump is working inside an air pocket (switch the pump off and then back on a few minu-
tes later, after bleeding the system);
The delivery piping is clogged, the ball intercept valves or the gate valves are partially closed.
The pump operates intermittently:
Check if one or more of the following conditions are present:
Liquid too hot (exceeding 40 °C)
Liquid too cold (below 0°C)
The pump working with an excessively high number of start-ups/hour.
The fluid level in the tank is not sufficent to operate the pump
The power supply voltage is outside the required limits (+/- 5%)
The impeller or the blades are obstructed by an obstacle that prevents correct rotation
If the fault persists, contact technical support.
If the pump stops unexpectedly, the reason may be one of the following:
Broken bearing.
Burning or loss of charge of the winding, which therefore is faulty.
Excessive power supply overload.
If the cause is excessive power supply overload, the installer may correct the power supply;
in the other cases contact the qualified technical support service.
If the user detects and extended intermittent operation of the electric pump, it will be neces-
sary to identify the cause, which may be due to wrong use. If after switching the pump off and
then back on, the intermittent operation persists, call DRENO POMPE technical support, or
DRENO POMPE qualified personnel.
IN CASE OF ANY DOUBTS ALWAYS CONTACT A TECHNICIAN QUALIFIED BY
DRENO POMPE (*), OR DIRECTLY THE TECHNICAL SUPPORT OF DRENO POMPE AT NO.
+ 39 0429 73276, OR BY E-MAIL AT ufficiotecnico@drenopompe.it
(*) a technician qualified by Dreno Pompe would be an individual possessing a Dreno Pompe qualified