Use & Care Manual
Installation Instructions
CONNECT RANGE TO GAS SUPPLY:
1.INSTALL MALE 1/2" FLARE UNION ADAPTER TO 1/2" NPT INTERNAL THREAD ELBOW AT
INLET OF REGULATOR.ON MODELS EQUIPPED WITH STANDARD TWOIN
BURNERS,INSTALL THE MALE PIPE THREAD END OF THE 1/2" FLARE UNION ADAPTER TO
THE 1/2" NPT INTERNAL THREAD AT INLET OF PRESSURE REGULATOR.USE A WRENCH
ON THE REGULATOR FITTING TO AVOID DAMAGE.
2. INSTALL MALE 1/2" OR 3/4" FLARE UNION ADAPTER TO THE NPT INTERNAL THREAD OF
THE MANUAL SHUT-OFF VALVE, TAKING CARE TO SECURE THE SHUT-OFF VALVE TO
KEEP IT FROM TURNING.
3. ""THE GAS INLET PRESSURE FOR CHECKING THE REGULARTOR SETTING IS 6"
W.C( NATURE GAS) AND 11" W.C(LP GAS) CONNECT FLEXIBLE GAS LINE CONNECTOR TO
THE REGULATOR ON THE RANGE. POSITION RANGE TO PERMIT CONNECTION AT THE
SHUT-OFF VALVE.
4. WHEN ALL CONNECTIONS HAVE BEEN MADE, MAKE SURE ALL RANGE CONTROLS
ARE IN THE POSITION AND TURN ON MAIN GAS SUPPLY VALVE.
5. LEAK TESTING OF THE APPLIACNCE SHALL BE CONDUCTED ACCORDING TO TEH
MANUFACTURER'S INSTRUCTIONS.USE SOME SOAP WATER (50% WATER AND 50%
SOAP) OR A LEAK DETECTOR AT ALL JOINTS AND CONNECTIONS TO CHECK FOR LEAKS
IN THE SYSTEM. DO NOT USE A FLAME TO CHEC FOR GAS LEAKS.
6. THE APPLIANCE MUST BE ISOLATED FROM THE BUILDING'S GAS SUPPLY PIPING
SYSTEM BY CLOSING ITS INDIVIDUAL MANUAL SHUT-OFF VALVE DURING ANY
PRESSURE TESTING OF THE GAS SUPPLY PIPING SYSTEM AT TEST PRESSURE EQUAL
TO OR LESS THAN 1/2" PSIG(3.5kPA).
20
www.caloricappliances.ca