RISK OF ELECTRIC SHOCK!
WARNING
Electrical Grounding In-
WARNING
structions: This appliance is
equipped with a three-prong (grounding) plug
for your protection against shock hazard and
should be plugged directly into a properly
grounded three-prong receptacle.
ALWAYS use the electrical power (voltage and
frequency) specified on the model plate of the
heater.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
For use with Natural Gas (NG)
WARNING
only.
– Use heater in accordance with all local codes.
In the absence of local codes, refer to The
National Fuel Code, ANSI Z223.1.
– This heater is shipped from the factory for use
with Natural Gas (NG) only. Do not convert to
any other gas. Installation shall conform with
local codes or, in the absence of local codes,
with National Fuel Gas Code ANSI Z223.1/
RISK OF FIRE! DO NOT POSITION HEATER IN A DOWNWARD ANGLE. ALWAYS
WARNING
LOCATE HEATER ON A STABLE AND LEVEL SURFACE (SEE FIGURE 1)!
Figure 1
1. Remove all packing items applied to heater for
shipment. Keep plastic cover caps attached to
inlet connector and hose / regulator assembly
for storage.
2. Remove all items from carton
© 2019 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A
SAFETY INFORMATION (CONT.)

UNPACKING

FUEL SOURCE
The hose assembly shall be
WARNING
pro­ t ected­from­traffic,­building­
material­and­contact­with­hot­surfaces­both­
during­use­and­while­in­storage.
NFPA 54 and the National Gas and Propane
Installation Code, CSA B149.1.
– Gas supply connections should be checked by
using a 50/50 soap and water solution. Never
use a flame to check for gas leaks.
– Locate NG source at least 6 feet (10 ft. in
Canada) from the heater, and do not direct
heater discharge towards the NG source
unless it is at least 20 feet from the heater.
– Use only the regulator and hose assembly
provided with this heater. Inspect the
regulator/hose assembly prior to each use of
the heater. If there is excessive abrasion or
wear, or if the hose is cut, replace it with the
proper assembly shown in the parts list, prior
to using the heater.
Manifold, Minimum and Maximum Inlet Pressure
Man.
Min.
Max.
X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X
3. Check all items for shipping damage. If the
heater is damaged, promptly inform dealer
where you purchased the heater.
The Natural Gas (NG) pressure
CAUTION
regulator supplied with the
heater must be used without alteration.
5
Natural Gas Forced Air Heater User's Manual
MH-150NGT-GFA-A
3.0 in. W.C.
5.0 in. W.C.
14.0 in. W.C.