• Power the device.
• Check that the red LEDs of the N.C. contacts are on and the green LEDs of the N.O. contacts are off.
• Check by tripping the limit switches (if used and enabled with the appropriate DIP switches) that the corresponding LEDs go off.
• Check by passing through the photocell beam (if used and enabled with the appropriate DIP switch) that the corresponding LED
goes off.
• Check that the motors are locked and ready for operation with the GATE AT HALFWAY ITS TRAVEL.
• Remove any obstacles in the range of action of the gate and then give a START command.
• Upon the first command, the control unit starts an opening phase; check that the gate moves in the correct direction. If not,
cut the power to the control unit and invert the wires of terminal M1 (position 1-3 for motor 1 and 4-6 for motor 2). Repower
the control unit and give a START command.
• During motion, turn the FORCE trimmer anticlockwise until finding the desired force/speed value.
• Check proper functioning of the automated device.
13 - SUMMARY OF FLASHLIGHT SIGNALLING
Device
Frame intercepted before motion
The manufacturer:
GI.BI.DI. S.r.l.
Via Abetone Brennero, 177/B,
46025 Poggio Rusco (MN) ITALY
declares that the product:
F4 PLUS ELECTRONIC CONTROL UNIT
is in conformity with the following EEC Directives:
• LVD Directive 2006/95/CE and subsequent amendments
• EMC Directive 2004/108/CE and subsequent amendments
and that the following harmonised standards have been applied:
• EN60335-1
• EN 61000-6-2, EN 61000-6-3
Date 15/06/2017

CE Declaration of conformity

Signalling
3 slow flashes
The Legal Representative
UK
Effect
Gate/door locked
Michele Prandi