Lift-Rite PRO LIFTER M Manuel D'instructions Et D'entretien page 69

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fault
Pump does not take a
full stroke
Lift, neutral and lowering
positions do not func-
tion correctly
The forks drop after
every stroke
Motor does not operate
Charger does not
charge
Daily service and function checks
Troubleshooting
Cause
Air in the hydraulic system
Insufficient hydraulic oil
The opening valve open/
does not close correctly
Leakage from the valve cone
Emergency stop key
depressed
Emergency stop key not
inserted
Batteries completely dis-
charged
Brake not released
Blown fuse
Blown fuse or interrupted
charging cable (indicated by
yellow blinking LED).
Battery voltage under 21.6 V
(indicated by both the green
and yellow LEDs blinking).
Charger overheated (indi-
cated by the green and yel-
lows LEDs blinking
alternately).
© Lift-Rite 232649-003
69
Action
Pump 5 strokes with lowering valve
open
Add oil to filler plug level
Adjust the setting of the valve chain
using adjuster nut
Replace the valve cone and washer
Pull up the emergency stop key to the
travel position.
Insert the key and turn it to the travel
position.
Charge the batteries.
Check whether the safety switch
against collisions was depressed as a
result of a collision and also the brake
switch.
Replace the fuse (under the battery
cover: 30 A rating for fuse close to the
side; 5 A rating for fuse close to centre).
Replace the fuse (5 A) or the charging
cable.
Inspect the fuse and measure the bat-
tery voltage. Replace the fuse or the
battery/batteries.
Allow the charger to cool down and try
charging later. If the problem remains,
replace the charger.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lec 1000 m/pst plusLec 1000 mu

Table des Matières