Magnetic Key; Factory Settings; Flushing Programmes; Service Programmes - DURAVIT DuraStyle 280631 Série Notice D'utilisation

Masquer les pouces Voir aussi pour DuraStyle 280631 Série:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 22

3.3 Magnetic key

The magnetic key is used to select all the functions of the electronic urinal by holding it in front of
the right-hand control unit sensor.

3.4 Factory settings

The electronic urinal has the following factory settings:
Settings
Detection time/dwell time:
Flushing duration:

3.5 Flushing programmes

Flush approx. 0.3 litres at 3.5 bar flow pressure
The flush volume depends on the pressure and cross-sectional build of the pipe.
Standard (P1)
The Standard flushing programme is set in the factory and is suitable for locations where a flush
is required after each use.
Hybrid (P2)
With the hybrid programme, the interval can be set individually to define after now many uses a
flush is triggered (10., 20., 30., 40. or 50). uses).
The flushing programme is suitable for hotels, restaurants, exhibition halls, airports and other
public facilities.

3.6 Service programmes

5-minute flush stop (S1)
In order to manually clean the electronic urinal, the flushing programme is deactivated for 5 min-
utes. Then a full flush occurs and the chosen flushing programme is reactivated.
Intermittent flushing (S2)
In order to allow e.g. a descaling product time to work, the flushing programme is deactivated for
2 minutes. Then 5 flush cycles occur within 10 minutes, with a reduced flush every 2 minutes. The
final flush is a full flush and then the chosen flushing programme is reactivated.

4. Start-up

To prevent the control unit from being activated unchecked, the stickers on the sensors must
be left on until the electronic urinal is started up.

4.1 Activating the control unit

> Pull off the stickers on the sensors.
The start-up mode will then be active for 5 minutes.
> Hold your hand in front of both sensors, a slight distance away from them.
1 short signal tone will sound and then the control unit will be activated.
> Now move away and take away any objects in the control unit's range.
The control unit alignment takes approximately 12 seconds and signal tones will sound during
the process. Then a full flush will occur and the electronic urinal will be ready for use.

4.2 Resetting the system (S6)

If you reset the system, the chosen programmes and settings are reset. Then you will be able to
select programmes and settings again.
Refer to page 2 for a diagram showing the signal sequence.
> Hold the magnetic key in front of the right-hand sensor.
Within approx. 3  seconds, several short signals will sound. Then 8 long signals will sound,
whereby a longer pause of approx. 6 seconds will occur after the 5, 6 and 7th signal tone.
> Remove the magnetic key.
18
Time
9 seconds
2 seconds

Publicité

Table des Matières
loading

Table des Matières