Operation
Display of operating status
The operating status of the KEMPER HS2 hygiene Flushing Box is displayed on the control
unit. The control unit is accessible after the cover plate has been removed.
Remove the cover plate.
Displays on the control unit
OK Err
1
2
3
4
1
LED green <OK>
2
LED red <Err>
3
<Test> button
4
Buzzer
0
Operating states
Table 2: Operating states
Element
Status
LED green
Flash pulse short Normal operation, operating voltage on
Flash pulse long
On
Off
LED red
On
Flashing
Off
Buzzer
On
1)
Off
<Test> button Press button
1)
The buzzer can be suppressed with the <Test> button. If the malfunction still persists after 24 hours, the buzzer is
activated again.
Maintenance Manual KHS HS2
Test
Meaning
Normal operation, Bluetooth interface active
Solenoid valve opened
Operating voltage off
Malfunction, diagnosis with KEMPER HS2 app
Warning, diagnosis with KEMPER HS2 app
Normal operation
Malfunction, diagnosis with KEMPER HS2 app
Test solenoid valves
With active Bluetooth interface: disconnect
In case of malfunction: suppress buzzer
5