Hepa Filter Replacement (Optional); Motor Cooling Fan Inspection And Cleaning; Tightness Inspection; Vacuum Cleaner Disposal - Diamatic BDC-3140P 230V/60Hz Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

HEPA filter replacement (optional)

Figure 11
1
Air inlet hose
2
Filter cover
3
Release lever
4
HEPA filter
Before proceeding with these operations, turn off the vacuum
cleaner and remove the plug from the power socket.
Remove the air inlet hose (1).
Use the levers (3) to remove the cover (2).
Remove the filter (4).
Assemble the new filter and install all the components in
the reverse order of removal.
Dispose of the old filter according to the laws in force.

Motor cooling fan inspection and cleaning

Periodically clean the motor cooling fan to prevent the motor
from overheating, especially if the vacuum cleaner is used in
a dusty place.

Tightness inspection

Figure 12
1
Suction connecting hose
2
Hose
Hoses check
Make sure that the suction connecting hose (1) is in a
good condition and correctly fixed.
If the hose is damaged, broken or badly connected to the
unions, it must be replaced.
When sticky materials are treated, check for possible clogging
along the hose (2), in the inlet and on the baffle plate inside the
filtering chamber.
Scrape the inlet from the outside and remove the
deposited waste as indicated in the figure.
Figure 13
1
Gasket
2
Screws
3
Filtering chamber
Filtering chamber tightness check
If the gasket (1) between the container and the filtering
chamber (3) fails to guarantee tightness:
Loosen the four screws (2) that lock the filtering
chamber (3) against the vacuum cleaner structure.
Allow the filtering chamber (3) to lower down and
tighten the screws once it has reached the tightness
position (2).
The gasket (1) must be replaced if it is torn, cut, etc...
07/2008

Vacuum cleaner disposal

Dispose of the vacuum cleaner in compliance with the laws in
force.

Wiring diagrams

Figure 14 - 15
Item
Part
Q1
Main switch
Q2
Circuit breaker
KM1
Contactor
TS2
Cyclic timer

Recommended spare parts

Code
Description
S08BL33008
Filter cartridge
8 17026
Filter gasket
8 17753
HEPA filter cartridge
9
BDC-3140P
Code of the model
230V/60Hz 400V/50Hz 440V/60Hz
8 39989
8 39535
8 39916
8 39014
8 39726
8 39726
8 39726
8 39102
8 39281
8 391105
8 39838
8 391107
Quantity
3
3
1
C324
I
GB
F
D
E

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bdc-3140p 400v/50hzBdc-3140p 440v/60hz

Table des Matières