The equipment must be installed in a ventilated location that is easy to access, far from any heat source and near a power socket.
It should be fixed to the wall using the bracket supplied on a wall capable of supporting the weight of the machine. The unit should be fixed at least
60 cm above the floor so that the dust tank can be emptied. It is important to leave enough space either side of the unit to facilitate its fitting and
maintenance.
2.2. Installation of the CVC unit in a cupboard
In this configuration, it is mandatory to connect the unit to an external
discharge system. The unit must be installed using the wall bracket, far
from any heat source and near a power socket outlet. It is important to
respect distances defined on the following drawing to facilitate its fitting
and maintenance.
You must install two ventilation grids of at least 10 x 10 cm at the top
and bottom of the cupboard to ensure the cooling necessary for the