Technical Specifications

Model
120S
240S
240D
Display range: 0°C to 70.0°C (32°F to 158°F)
Ambient setpoint range (A/AF modes): 5.0°C to 30.0°C (40°F - 86°F)
Floor setpoint range (F mode): 5.0°C to 40.0°C (40°F - 104°F)
Floor limit range (AF mode): 5.0°C to 40.0°C (40°F - 104°F)
Resolution: 0.5°C (1°F)
Heating cycle length: 15 minutes
Data protection: In the event of a power failure, most settings are saved. However the time and Daylight Saving Time must
be set if the power failure lasts more than 6 hours. The thermostat will return to the mode that was active prior to the power
failure.
Supply
120 VAC, 50Hz/60Hz
240 VAC, 50Hz/60Hz
208 VAC, 50Hz/60Hz
240 VAC, 50Hz/60Hz
208 VAC, 50Hz/60Hz
Maximum current
Maximum wattage
16.7 A
16.7 A
15 A
19
TH115 (120S/240S/240D models)
Wiring
2000 W
4 wires / single pole
4000 W
4 wires / single pole
3470 W
3600 W
4 wires / double pole
3120 W