Rinse all parts with cold water
immediately after use. Place pump parts
in a clean wash basin used only for
washing infant feeding equipment. Do
not place pump parts directly in the sink
because germs in sinks or drains could
contaminate the pump.
Hand wash all parts of the Breastmilk
Expression Set using warm soapy water.
A teat brush may be used to scrub the
hard plastic pieces of the Breastmilk
Expression Set, but should not be used
on the white valve or diaphragm.
Rinse parts with running clean, warm
water, or by submerging in fresh water
in a separate basin that is only used for
cleaning infant feeding equipment.
Place parts in a pot and cover with water
making sure there is room for all of the
parts to float freely in the pot.
Bring the water to a boil and allow to
boil for 5 minutes.
After boiling remove the parts from the
pot with tongs and place the pieces
neatly on a clean paper towel or in a
clean drying rack and allow them to air
dry. Do not use a dish towel to rub or
pat items dry because doing so may
transfer germs to the items.
Allow the parts to dry completely before
assembly and use. Partially dried parts
may affect the operation of the pump.
Once parts are dry they can be stored in
a clean plastic tub with a lid or in a clean
plastic zipper bag.
Clean your wash basin and bottle and/or
teat brush after each use.
The pump unit should be wiped down with
a clean paper towel or soft cloth after use.
The pump unit should never be put into
water or other liquids for cleaning.
Parts can be cleaned in a steam or
microwave steriliser. Be sure to follow the
manufacturer's instructions.

2.3 Assembling the Breast Pump

a
Diaphgram Cap
b
Diaphgram
c
ComfortFit® Breast Cushion (25mm)
d
Breast Cushion Body
e
White Valve
f
160ml (5oz) Bottle
a
b
c
d
e
f
2

2.4 Using the Breast Pump

The Lansinoh
Compact Single Electric Breast
®
Pump is very easy to use, offering several
settings that you can customise to maximise
your milk production and comfort.
Let-Down and Expression Phases
When babies breastfeed, they start with
quick sucking to stimulate your milk
let‑down and flow. Once your milk has let
down, the baby draws the milk out with
slower, deeper sucks. To simulate this
natural rhythm, the Lansinoh
Single Electric Breast Pump offers 2
phases – the Let‑Down Phase and the
Expression Phase.
Let‑Down Phase is a faster pumping style
which mimics the short, rapid sucking
your baby uses to initiate milk flow
Expression Phase mimics the slower,
deeper sucking of feeding and features
5 adjustable suction levels that can be
tailored for your comfort.
The switch between the 2 phases can
be easily operated using the Let‑Down/
Expression toggle button
Phase is identified on the keypad with
slowly dimming LED lights. Expression
Phase is identified on the keypad with still
LED lights.
When the pump is turned on, it starts in
Let‑Down Phase and will automatically
switch to the Expression Phase after 2
minutes. If your milk starts flowing before
the 2 minute transition, you can switch to
Expression Phase at any point by pressing
the
button. You can always return to the
Let‑Down Phase when needed by pressing
the
button again.
Operating the Breast Pump
Ensure that the breast pump has been
properly cleaned. Wash your hands
thoroughly and make sure your breasts
are clean.
Ensure the breast pump and the Breastmilk
Expression Set have been correctly
assembled and the silicone tube is securely
attached to the pump via the tubing
connector and to the diaphragm cap.
Hold the Breastmilk Expression Set to
your breast with the centre of your nipple
extending towards the tunnel of the
ComfortFit® breast cushion.
Make sure the breast completely fills
the ComfortFit® breast cushion so that a
vacuum is formed and no air escapes.
The Breastmilk Expression Set and nipple
tunnel must tilt slightly downward to
allow milk to flow naturally toward the
bottle.
Press and hold the On/Off button
a few seconds to turn the pump on.
The breast pump will always start
in Let‑Down Phase Level 3 and will
automatically switch to Expression
Phase after 2 minutes. If your milk starts
flowing before the 2 minute transition,
you can switch to Expression Phase at
any point by pressing the
You can always return to the Let‑Down
Phase when needed by pressing the
button again.
You can increase the suction level by
pressing the
the suction level by pressing the
button. A maximum of 5 LED lights will
illuminate depending on the selected
suction level.
Note: If at any time the suction becomes
Compact
®
uncomfortable, reduce it by pressing the
button
When a pumping session is finished, turn
the pump off with the On/Off Button
Ensure there is no suction on the nipple
before removing the ComfortFit® breast
cushion from the breast. If necessary,
break the suction by inserting a finger
between the breast cushion and the
breast. Once the suction is broken,
the ComfortFit® breast cushion can be
removed safely.
Carefully remove the bottle from the
. Let‑Down
breast cushion body and close the bottle
with the sealing cap provided. Please
follow the breastmilk storage guidelines
as outlined in Section 3.
Note: If the pump unit is left on and
unattended for more than 60 minutes, it
will automatically power off
Power Options
The pump may be operated using the
following power supply modes:
AC adapter
Connect the adapter to the power
connector socket, which is located on
the same side of the pump as the On/
Off button. Plug the AC Adapter into
an available electrical outlet. Electrical
safety can only be achieved when
the breast pump is connected to the
AC Power Adapter supplied with the
product (See "Technical Data" section).
Power bank (not included)
Connect the power bank USB cable to
the power connector socket, which is
located on the same side of the pump
as the On/Off button. Electrical safety
can only be achieved when the breast
pump is connected to the power bank
specified power supply. (See "Technical
Data" section)
We recommend using your pump with the
AC adapter provided

2.5 Breast Cushion Sizing

for
button.
button. You can decrease
.
When you are
pumping only
your nipple and a
Nipple
small amount of
your areola
should be pulled
into the breast
Areola
cushion tunnel. If
a large amount of