Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower may only be used for bathing, hygiene
and body cleaning purposes.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The product is not designed to be used with steam
baths!

Technical Data

Operating pressure:
Recommended operating pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Fault
Head shower extremely leaky
4
max. 0,6 MPa
0,2 - 0,4 MPa
(1 MPa = 10 bar = 147 PSI)
max. 60°C
max. 70°C / 4 min
Cause
- Head shower soiled / scaled
Assembly (see page 38)
English

Symbol description

Do not use silicone containing acetic acid!
Dimensions (see page 41)
i
Installation example (see page 32)
Flow diagram (see page 32)
Spare parts (see page 46)
Cleaning (see page 44)
Remedy
- Clean / descale head shower
(see page 44)