INSTALLATION AND MAINTENANCE OF YOUR RADIATOR
EN
STANDARDS Class II - IP44 - Double insulation.
They also comply with the European Directive 2004/108/EC (CE marking on all the
appliances).
2. OPERATINg INSTRUCTIONS OF YOUR RADIATOR
To make the most of your radiator and for greater comfort, we would ask you to take the following
recommendations into account:
2.1 Positioning
• The appliance can be installed in the zones 2 and 3 of the bathroom (see side drawing). In accordance with the
latest electrical safety regulations, and in such a way that the controls cannot be reached by a person using the
bath or shower.
• The appliance should never be installed with its power supply in high position.
• The power supply must not be put on the ground.
2.2 Brackets
For the correct installation of radiators it is essential that the fixing of the radiator
is carried out in such a way that it is suitable for intended use AND predictable
misuse. A number of elements need to be taken into consideration including the
fixing method used to secure the radiator to the wall, the type and condition of
the wall itself, and any additional potential forces or weights that may happen to
be applied to the radiator, prior to finalising installation.
In any case, it is highly recommended that the installation is made by a qualified
professionnal or people that has equal qualifications. the installation of the
appliance must be compliant to the current regulations of the country it is set in.
• The radiator must be installed on a vertical wall using the wall mounts supplied.
• For correct heater installation, when the appliance is located close to a wall, it is essential to leave a
minimum distance of 250 mm to access the installation.
• Use bracket screws suited to your type of wall, secure the heater on the wall using the screws
provided with the radiators.
14 | P16MI394 - A02 - 04/15
RETTIG_TINOS_E and PAROS E_4 languages_2015.indd 14
• The drawing indicates the correct position of the appliance.
• The lower part of the radiator must be within a minimum distance of
150 mm from the ground,
• The radiator must not be installed within 50mm of a wall or
underneath a power outlet,
• Any installation of a shelf above the radiator must be carried out
over 150 mm of it,
• It is recommended to perform the installation, if possible, close to
locations with high heat losses (windows etc) and using screw fasteners
appropriate to the nature of the wall,
12/05/15 10:23

Publicité