Power
Load
Pilot Wire
Floor sensor
NOTE 1
If a contactor is used between the thermostat and the load, install a
snubber at the contactor's coil terminal to ensure the proper operation
of the thermostat.
NOTE 2
Optional (see page 10).
NOTE 3
For the proper operation of the thermostat, the floor sensor must be
centered between two heater wires having a maximum temperature
of 80°C (176°F). The floor sensor wire must not cross any heater wire
or be placed close to it.
NOTE 4
Ensure that the wires are tightly secured to the terminals. Apply a
minimum torque of 0.5 Nm (4.4 Lb/in) when tightening the screws.
NOTE 5
The terminals are designed to handle a cross-section of wire
measuring 0.33 to 3.1 mm
Terminals 1 & 5
Terminals 2 & 4 (see note 1)
Terminal 3 (see note 2)
Terminals 6 & 7; no polarity (see note 3)
2
.
7