GE Druck PV 411A User Manual

Operation

WARNINGS
1
B
EFORE APPLYING PRESSURE
ARE CORRECT AND EQUIPMENT IS INTERNALLY CLEAN AND FREE
FROM DAMAGE
2
M
AKE SURE THAT ALL EQUIPMENT IS TO THE CORRECT PRESSURE
.
RATING
3
D
O NOT EXCEED THE MAXIMUM OPERATING PRESSURE STATED IN
THE SPECIFICATION
4
O
BSERVE THE RELEVANT HEALTH AND SAFETY PRECAUTIONS
Note:
Wherever possible, use o-ring seals in the connection ports this is the
recommended method of sealing.
1 Inlet (reservoir) port
2 Outlet port
3 Volume adjuster
4 Limit adjuster
5 Scissor-action handles
6 Outlet port
7 Selector valve
8 Pressure relief valve (see figure 3)

Pressure/vacuum Configuration

In pressure mode, air/fluid is drawn in through the inlet port (1) on the top of
the pump and forced out through the two outlet ports (2 & 6).
In vacuum mode, the air/fluid flow is reversed as air/fluid is drawn in through
the top and rear outlet ports (2 & 6) and expelled through the inlet port (1).