ROBLIN Lido/2 Murale Clean-air Mode D'emploi Et Installation page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

- green / yellow : earth - blue : neutral - brown : live
As the colours of the wires in the mains lead of this appliance may not correspond with the coloured
markings identifying the terminals in your plug, proceed as follows.
- The wire which is coloured green and yellow must be connected to the terminal in the plug which is
marked with the letter E or by the earth symbol or coloured green or green and yellow.
- The wire which is coloured blue must be connected to the terminal which is marked with the letter N or
coloured black.
- The wire which is coloured brown must be connected to the terminal which is marked with the letter L or
coloured red.
ATTENTION Do not forget to use adequate plugs to the support brackets. Enquire after the manu-
facturers. Do an embedding if necessary. The manufacturer accepts no responsibility in case of a
faulty hanging due to the drilling and the setting up of plugs.
GB
1) Draw a vertical line onto the wall from the centre of the cooking appliance up to the ceilling, using a
spirit level and a marker pen as illustrated in Fig. 3 - item 1. This is to ensure the correct alignment
of the chimney hood.
2) Place the brackets item 2 on the wall about 40 mm from the ceiling ; aligning its centre on the vertical
line. Mark the two eyelet holes of the bracket onto the wall. Drill the holes for the fixing bracket using
an 8 mm masonry bit. Fix the chimney bracket item 2 and the recirculation spigot (R) using the 4.5
x 50 mm screws and rawl plugs supplied.
3) Mark the hole centres for the canopy fixing brackets item 4 at item B mm as illustrated in Fig. 6. Drill
the 4 holes for the fixing brackets using an 8 mm masonry bit. Fix the wall brackets item 4 using the
4.5 x 45 mm screws and rawl plugs supplied.
4) Hook the canopy item 5 onto the wall brackets item 4 as illustrated in Fig. 6. To ensure the cooker
hood is aligned correctly adjust the screws on the top of the canopy. Unhook the canopy from the
wall and drill the hole for the security fixing screw.
5)
a. Fit the recirculation spigot R onto the upper chimney wall bracket using the same fixing screws (Fig.
4 item 2). The location of the grid must be located in front of the slide (G) of the deflector (R) .
b. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot
and secure the connections with appropriate clamping rings or adhesive tape.
c. Before fitting the chimney to the canopy make the electrical connection as described in the section
titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor.
d. Insert the charcoal filter into the base of the motor housing and secure the filter with two metal secur-
ing straps item A as illustrated in Fig. 7.