DOCRILUC VE-10E-10 Manuel D'utilisation Et D'entretien page 21

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DOOR SEALS
The rubber door seals are designed to ensure the closure of the doors to the cold chambers and to guarantee the sealing of the doors against
external elements.
A magnetic strip is housed on the inside of the rubber seal, which adheres it to the frame of the unit. Over time granular particles can become
stuck in the seal due to the effect of the magnet and these can rust and cause stains.
It is recommended that these door seals are kept free from foreign bodies that can cause rust, as well as fatty deposits which, over a long period
of time, can affect the rubber of the door seal.
Clean them with water, using neutral soap and a damp cloth. DO NOT USE DETERGENTS OR ABRASIVE PRODUCTS.
REPLACEMENT OF LAMPS
The lighting is controlled by a switch on the dashboard of the refrigerating equipment. To replace fluorescent lamps, do the following:
The power can be seen in the fluorescent own or sticker indicating the maximum power.
9. OPERATINAL TEST
CHECKS IN TE EVENT OPERATIONAL FAILURE
In some situations, operational failure can arise due to simple causes that users themselves can solve, which is why prior to requesting the
intervention of a specialised technician, we recommend that you carry out the following checks.
The appliance does not work
- Check that it is correctly plugged in.
- Check that electricity reaches the power outlet.
- Check that general switch is in the
The internal temperature is too high
- Check that there is no heat source nearby.
- Check that the grill is not obstructed.
- Check the Set-point.
- Check that the product loaded is perfectly distributed, without blocking the interior air ventilation exits and that the time elapsed since loading
has been sufficient to chill the products.
- Check if the evaporator has ice.
- Check that the condenser is not obstructed.
- Check that the appliance is functioning normally.
In the event of strange or excessive noises
- Check the levelling of the unit as this may cause vibrations.
- Check that there is no object rubbing against any movable element of the refrigerated unit.
-Disconnect the unit from the power supply.
-Remove the protective of polycarbonate with the help of a tool, inserting one end and
pull out.
-Rotate 90º and extract fluorescent.
-Fluorescent change the other of the same characteristics..
-Enter the tube aligning the pins with brackets..
-Rotate 90º fluorescent to adjust.
-Replace the protective of polycarbonate.
-Connect the unit to the power supply.
Mod
W
T8
15
T8
18
T8
30
T8
36
I/ON
position.
L (mm)
Ø (mm)
438
26
590
26
895
26
1200
26

Publicité

Table des Matières
loading

Table des Matières