Installation Procedure; Prepare Installation Space; Install Appliance; Connect Electrical Supply - Gaggenau VK 230 714 Instructions D'installation

Masquer les pouces Voir aussi pour VK 230 714:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Procedure

Prepare Installation Space

Create the cut-out in the countertop for one or several
Vario appliances according to the installation diagram.
The angle of of the cut surface to the countertop must
be 90°.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat-resistant manner.
Some solid surface countertops require special
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
Observe minimum distance between appliance
underside and furniture parts of
When installing multiple Vario appliances:
account space requirement for VV 200 connection
strip between the appliances. Appliances can also be
installed in individual cut-outs, bearing in mind a
minimum distance between the appliances of 1
(40 mm).

Install Appliance

,
WARNING:
Before you plug in an electrical cord
or turn on power supply, make sure all controls
are in the OFF position.
Make a mark exactly in the center of the cut-out.
1
Fasten the mounting rails to the front and rear
edge of the cut-out. The leading edges of the
mounting rails must lie upon the countertop. The
center marking of the mounting rails must
correspond precisely with the center marking of
the cut-out.
Note: For stone countertops, adhere the
mounting rails with temperature-resistant duel-
component adhesive (metal on stone).
3
/
" (10 mm).
8
Take into
/
"
9
16
For combination with the VD 201 appliance cover:
2
Mount appliance cover to appliance prior to
installation (see VD 201 Installation Instructions).
Insert appliance in cut-out. The snap-in pins on
3
the appliance must lie precisely on the clamp
springs. Press appliance firmly into the cut-out.
The snap-in pins on the appliance must snap into
the clamp springs.

Connect Electrical Supply

Refer to data plate for more information. See "Service"
for data plate location.
The branch-circuit breakers ampacity, the wire sizes
and the connections must be conform to the
requirements of the National Electrical Code or
Canadian Electrical Code and all local codes and
ordinances.
Attach flexible conduit to the junction box. Connect
the lead wires to the junction box supply wires in
proper phase:
black (L1) to black
red (L2) to red
green to ground
The mains connecting cable must at least correspond
to the type SJTO 3x16 AWG 105°C. The mains
connecting cable must only be purchased through and
connected by an authorised specialist.
Connection with a plug
Plug has to be conform with NEMA
CONFIGURATIONS FOR PLUGS AND
RECEPTACLES.
The appliance must be properly grounded.
Plug must be rated not less than type 6-20 P (2-
pole 3-wire grounding).
Only a qualified electrician should connect the
plug.
Install a socket outlet earthed in accordance with
regulations approx. 27" (70 cm) above the floor
5

Publicité

Table des Matières
loading

Table des Matières