The Altrad Belle 'PCX 60A' range is designed to give many years of trouble free operation. It is recommended that an approved Altrad
Belle dealer carries out all major maintenance and repairs. Always use genuine Altrad Belle replacement parts, the use of spurious
parts may void your warranty.
Before any maintenance is carried out on the machine, switch off the engine and disconnect the HT lead from the sparkplug.
Always set the 'PCX 60A' on level ground to ensure any uid levels will be correctly read. Only use recommended oils (see chart
below).
Running In Period
When the 'PCX 60A' is rst used from new, the engine oil must be changed after the initial running in period (see engine manual for
full detail). The vibrator shaft case oil must be replaced after the rst 100 hours use, then after every 500 working hours. For detail on
vibrator shaft case oil replacement, see 'Vibrator unit'.
The belt tension should be checked after 4 hours use.
Routine Maintenance
Engine Oil
Air Filter
Spark Plug
Drive Belt
Oil / Fuel Type & Quantity - Spark Plug Type
Petrol Honda GX120
Vibrator
Service & Maintenance
Check Level
Change
Check Condition / Clean
Change
Tension
Quantity
Oil Type
S.A.E. 10W 30
S.A.E. 10W 40
Vibrator Unit.
Remove the plug complete with seal, check that the oil level reaches the bottom thread on the oil
plug hole. Top up as necessary with the correct oil (see chart).
Replace when necessary / Every 12 months
Fuel Type
(Litre)
0.6
Unleaded
0.22
N/A
8
First 4
First Month /
20 Hours
Hours
Capacity
Spark Plug
(Litre)
Type
BM6ES or
2.5
BPR6ES
N/A
N/A
3 Months
6 Months /
/ 50 Hours
100 Hours
Electrode
Gap (mm)
0.7 - 0.8
N/A