56
If the battery-charge level is allowed to discharge to the point that only one red light remains
illuminated (and begins to flash), all cleaning functions will automatically be disabled and the operator should drive the
machine straight to a suitable charge point.
57
The large capacity gel batteries are sealed for life and are totally maintenance free. The on-board charger
automatically monitors the charging process and will switch off when the batteries are
fully charged.
The machine charging point is located above the foot plate (See page 3 : Item 10).
Insert the charging lead (Fig.57) required for your country into the charging point and connect to a suitable power
supply (Fig.58).
Note: The Charging Lead supplied with your machine may differ than the lead shown.
Once the charging lead has been connected the red charging indicator will illuminate and the display panel will show
'INHIBITED'
The battery charge indicator display lights will flash in unison.
The machine will not operate.
To ensure a full charge, the machine should be left until the charging indicator shows green.
Once fully charged, disconnect the charging lead from both the power supply and the machine.
*Note
Charger viewing panel only available on certain models.
Machine Charging
Always ensure that the machine is switched off prior to charging.
The battery charge indicator displays the charge level of the batteries; when
fully charged, all meter lights are illuminated (see Fig.56).
As the machine is used and the batteries are discharged, the meter lights will
go out from right to left.
If the battery-charge level is allowed to discharge to the point that only the red
lights are illuminated, the operator must
consider charging the machine.
40
!
58
See page 44