INSTALLATION INSTRUCTIONS

The installation must be performed by a qualified electrical contractor. This contractor will take
the entire responsibility of the installation. The installation has to comply with the legislation and
the standards in force in your country.
How to stick the gasket:
The gasket supplied with the hob avoids all infiltration of liquids in the cabinet.
The gasket supplied with the appliance also allows to maintain in position the appliance, it is not
necessary to use another fixation system.
His installation has to be done carefully, in conformity of the following drawing.
Fitting - installing:
 Cut out sizes of the worktop:
 Ensure that there is a distance of 40 mm between the hob and the wall or sides.
 The hobs are classified as "Y" class for heat protection. Ideally the hob should be installed
with plenty of space on either side. There may be a wall at the rear and tall units or a wall
at one side. On the other side, however, no unit or divider must stand higher than
the hob.
 The piece of furniture or the support in which the hob is to be fitted, as well as the edges of
furniture, the laminate coatings and the glue used to fix them, must be able to resist
temperatures of up to 75 °C.
 The mural rods of edge must be heat-resisting.
 Not to install the hob to the top of a not ventilated oven or a dishwasher.
 To guarantee under the bottom of the hob casing a space of 20 mm to ensure a good air
circulation of the electronic device.
 If a drawer is placed under the work, avoid to put into this drawer flammable objects (for
example: sprays) or not heat-resistant objects.
 Materials which are often used to make worktops expand on contact with water. To protect
the cut out edge, apply a coat of varnish or special sealant. Particular care must be given
to applying the adhesive joint supplied with the hob to prevent any leakage into the
supporting furniture. This gasket guaranties a correct seal when used in conjunction with
smooth work top surfaces.
 The safety gap between the hob and the cooker hood placed above must respect the
indications of the hood manufacturer. In case of absence of instructions respect a distance
minimum of 650 mm.
 The connection cord should not be subjected, after building-in, to any mechanical
constraint (for instance constraint given by a drawer installed below).
 WARNING: Use only hob guards designed by the manufacturer of the cooking appliance
or indicated by the manufacturer of the appliance in the instructions for use as suitable or
hob guards incorporated in the appliance. The use of inappropriate guards can cause
accidents.
Reference
EKI6050/4Flex
EKI8050/4Flex
Stick the gasket (2) two millimeters
from the external edge of the glass,
after removing the protection tape (3).
Cut-size
560 x 490 mm
750 x 490 mm
35