Occupation balanced XLR-connection:
Occupation jack plug:
The occupation of the screw connctors is as follows:
Connection 1 = Signal +
Connection 2 = Signal -
Connection 3 = Shield

INSTALLATION

RACK MOUNTING
The equalizer is built for 19" racks/483mm. The minimum mounting depth is 185 mm. The height is 133 mm.
You can fix the equalizer with four screws M6 in the rack.
When mounting the equalizer into a rack, please make sure that there is a proper air circulation.
Please make sure that there is enough space around the device so that the heated air can be passed on.
The rack should be provided with a cooling fan.
Be careful when mounting the equalizer into the rack. Put the heaviest devices into the lower part of the rack.
Be aware that fastening the equalizer with four screws on the front panel is not enough. In order to ensure
safety, additional fastening by using ground and side bars is necessary.
If racks are to be transported or used for mobile use, additionally fasten the devices by connecting the rear
brackets with the side or ground bars of the rack. In this way, the equalizer cannot be pushed backwards.
The front panel alone is not designed to absorb acceleration forces occuring during transportation.
INPUTS
A good cable run improves the sound quality remarkably. Input cables should be short and direct, since high
frequencies will be mostly be absorbed if the cables are unnecessarily long. Besides that a longer cable may
lead to humming and noise trouble. If long cable runs are unavoidable, you should use balanced cables.
The inputs of your OMNITRONIC GEQ-231 FD are equipped with XLR and ¼" jack-sockets and screw
connectors.
Balanced use with XLR connectors
1
2
1 = Ground / Shield
2 = Hot (+)
3 = Cold (-)
3
Input
For unbalanced use pin 1 and pin 3 have to be bridged
Unbalanced use of
mono 1/4" jack plugs
Tip =
Signal (+)
Sleeve =
Ground / Shield
Tip
Sleeve
Strain relief clamp
16/27
2
1
3
Output
Balanced use of
stereo 1/4" jack plugs
Tip =
hot (+)
Ring =
cold (-)
Sleeve =
Ground / Shield
Tip
Ring
Sleeve
Strain relief clamp
For connection of balanced and
unbalanced plugs, ring and sleeve have
to be bridged at the stereo plug.