How To Use - Mediclinics M09A Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16

HOW TO USE

The hand dryer starts automatically when the hands are placed near the LEDs detection zone,
which is just next to the air outlet. Hand detection and the ensuring starting of the machine is
based on emission-reflection-reception of an IR light beam coming from the sensors. The
detection distance is between 120 and 150 mm approximately. (4.72 – 5.9").
For good hand drying it is advisable to rinse the hands properly in order
to remove totally any remains of soap.
In order to start the hand drying process, the hands must be rubbed
together at an approximate distance of 600 - 700 mm (2,36 - 2,76")
from the air output (see figure 15). The hand dryer will stop within 2 -
3 seconds, once the hands are removed.
The detection range can be adjusted by turning the potentiometer as
shown in figure 14.
The maximum time for which the hand dryer will function continuously is 60 seconds. After this
time, the hands must be removed from the hand dryer and placed next to it in the same zone
once more in order to start the hand dryer up again.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE
PREVENTIVE MAINTENANCE AND CLEANING
Adequate cleaning of the hand dryer will extend its useful life. It is recommended to remove any
dust accumulated inside the hand dryer at least once a year.
To clean the hand dryer correctly, take the following steps:
Disconnect the hand dryer from the power supply.
Remove the two lower screws that fix the casing to the base using the special spanner
provided.
Remove the casing as instructed in the chapter "Removing the casing" and place it on a
cloth, to prevent scratching or rubbing at all times.
Clean away the dust and remove any dirt accumulated inside the hand dryer, using a
dry cloth or a soft brush.
Clean from the air input to inside the motor (upper part of the nozzle) preventing dust or
dirt falling inside the turbine-motor assembly.
Carefully clean the dust away from around the electronic circuit located inside its box-
type housing. Carry out this operation taking maximum care not to damage any
component of the electronic circuit.
Use a soft cloth to clean the surface of the IR sensor protector screen.
APPLIANCE.