Method Of Use; Cleaning Method - Mediclinics E88-UL Manuel D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

METHOD OF USE

To dry correctly is recommended rising well to remove all traces of soap.
Button models:
Press the start button. Immediately after approach the hands to the
air outlet and rub them together. The hands can be gradually taken
away from the dryer and will continue drying up to a maximum
distance of 10-15 cm (4" - 6") .
The handryer works during 34 seconds. After that it stops and will
be ready to work again.
Automatic models:
These models operate by hand detection. If hands are held 10÷15
cm (4" - 6") from the air outlet, the dryer will start working.
Immediately after the hands can be gradually taken away from the
dryer and will continue drying up to a maximum distance of 10÷15
cm (4" - 6"). The machine will stop 2-3 seconds after use.
If the sensor is blocked due to vandalism, the dryer will completely
stop working.
Please let a minimum separation of 40 cm (16") between appliance
and any shelf, marble, worktop or washbasin.
PREVENTATIVE MAINTENANCE AND CLEANING
Correct cleaning of the unit will lengthen its working life considerably. When in use, the
machine will accumulate dust inside which should be cleaned out if used regulary, at
least once a year.

CLEANING METHOD

1- Disconnect the dryer current supply.
2- Unscrew the lockscrews using the special wrench.
3- Remove cover.
4- With a soft bristle brush, remove the accumulated dust in the scroll fan, rotating the
same by hand.
5- With the same brush, clean accumulated dust in from the rest of the components.
6- Clean the air inlet grill with a medium brush. Control of the motor brushes condition.
These should be replaced when its length is less than 3/16"(5 mm).
7- Once the maintenance process is completed, re-mount the cover, screw down the
lockscrews and connect up.