5 Installing

5.1 Control panel

For dimensions see '7 Overall dimensions'.
The panel is for fitting inside!
Use a hole cutter to cut a hole diameter 76 mm (3") in the instrument panel or in a
bulkhead. Fit the panel in the hole using the spring clamps supplied. If the back of the
panel will not be easily accessible all connections should be made first before position-
ing the panel in the hole.

5.2 Sensors

One or two sensors may be connected to the gas detector as desired. The sensor
must be positioned in the right place in the room in which a concentration of gas could
arise.
5.2.1 Selecting the right place for the sensor
The sensor detects both petrol vapour and carbon monoxide (CO).
Petrol vapour is denser than air and must be detected as low as possible.
Carbon monoxide is less dense than air and must be detected as high as possible.
Naturally, it is possible that both gases that are denser than air and less dense than air
can occur in an engine room.
All rooms for which this is important must naturally be well ventilated.
The sensor may be positioned at any angle.
The position of the sensor must be chosen so that it will always be out of the bilge
water!
5.2.2 Installing a 2
nd
sensor
If a second sensor is fitted later after originally only positioning one sensor during the
nd
installation of the gas detector the presence of the 2
sensor will automatically be
detected by the gas detector.
In order to measure the concentration of gas reliably the sensor must warm up for
1 minute after this.
20
100106.01
Gas detector PD1000