Télécharger Imprimer la page

VelLight LEDA200 Mode D'emploi page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
• IP44 rated
• low power consumption, high power output.
5.
Installation
Refer to the illustrations on page 2 of this manual.
1.
This luminaire does not have a built-in device to disconnect it
from the electric mains. Make sure to electrically isolate the
luminaire before installation or maintenance activities are
performed.
2.
Push the spike into the ground at the desired location.
3.
Connect the power cable [1] to a suitable 12V power source.
Make sure there is no strain on the cable; leave sufficient slack.
Warning: if the power cable is damaged, it must be replaced by
the manufacturer, his service agent, or a similar qualified person
in order to avoid any hazard.
4.
Tilt the lamp in the desired angle.
Caution: make sure the power cable is not crimped.
6.
Cleaning and maintenance
• All screws should be tight and free of corrosion.
• The electric power supply cables must not show any damage.
Have a qualified technician maintain the device.
• This luminaire does not have a built-in device to disconnect it from
the electric mains. Make sure to electrically isolate the luminaire
before installation or maintenance activities are performed.
• Wipe the device regularly with a moist, lint-free cloth. Do not use
alcohol or solvents.
• There are no user-serviceable parts.
• Contact your dealer for spare parts if necessary.
7.
Technical Specifications
power supply
LED
colour temperature
luminous flux
dimensions
weight
V. 03 – 22/08/2013
LEDA200
12VDC
1 x 1W high power LED
6500K
140 lm
Ø44 x 82mm (250mm spike included)
440g